Enzotech Ultra-X: If Looks Could Chill
by Wesley Fink on June 27, 2007 3:00 AM EST- Posted in
- Cases/Cooling/PSUs
CPU Cooling Test Configuration
The standard test bed for cooling tests is the EVGA NVIDIA 680i SLI motherboard. This is primarily based on the consistent test results on this board and the NVIDIA Monitor temperature measurement utility, which is part of the nTune program.
NVIDIA Monitor has a drop-down pane for temperature measurement which reports CPU, System, and GPU measurement. At this point reviews will concentrate on CPU temperature. In addition to the real-time temperature measurement, NVIDIA Monitor also has a logging feature which can record temperature in a file in standard increments (we selected every 4 seconds). This allows recording of temperatures during testing, which can then be reviewed when the stress tests are completed. There is also the handy reference of speeds and voltages in the top pane to confirm setup.
NVIDIA Monitor was compared to test results from the Intel TAT (Thermal Analysis Tool). Intel TAT CPU portions do function properly on the EVGA 680i motherboard, but the chipset-specific features do not operate as they should. Idle temperatures in TAT were in line with measured idle temps with NVIDIA Monitor. The CPU stress testing with TAT pushing both cores showed TAT stress temps at 80% CPU usage roughly corresponded to temps reported in our real-world gaming benchmark.
Other components in the cooling test bed are generally the same as those used in our motherboard and memory test bed:
All cooling tests are run with the components mounted in a standard mid-tower case. The idle and stress temperature tests are run with the case closed and standing as it would in most home setups. We do not use auxiliary fans in the test cooling case, except for the Northbridge fan attached to the 680i for overclocking. Room temperature is measured before beginning the cooler tests and is maintained in the 20 to 22C (68 to 72F) range for all testing.
Enzotech provided a small tube of premium Arctic Silver 5 with the cooler accessories, but we tested the Ultra-X with our standard premium silver-colored thermal compound. In our experience the thermal compound used makes little to no difference in cooling test results. This is particularly true now that processors ship with a large manufacturer-installed heatspreader. Our current test procedure uses this standard high-quality silver-colored thermal paste for all cooler reviews.
We test the stock Intel cooler at standard X6800 speed, measuring the CPU temperature at idle and while the CPU is being stressed. The CPU is stressed by running continuous loops of the Far Cry River demo. The same tests are repeated at the highest stable overclock we can achieve with the stock cooler. Stable in this case means the ability to handle our Far Cry looping for at least 30 minutes.
The same benchmarks are then run on the cooler under test at stock, highest stock cooler OC speed (3.73GHz), and the highest OC that can be achieved in the same setup with the cooler being tested. This allows measurement of the cooling efficiency of the test unit compared to stock and the improvement in overclocking capabilities, if any, from using the test cooler.
Noise Levels
In addition to cooling efficiency and overclocking abilities, users shopping for CPU cooling solutions may also be interested in the noise levels of the cooling devices they are considering. Noise levels are measured with the case on its side using a C.E.M. DT-8850 Sound Level meter.
This meter allows accurate sound level measurements from 35bdB to 130dB with a resolution of 0.1dB and an accuracy of 1.5dB. This is sufficient for our needs in these tests, as measurement starts at the level of a relatively quiet room. Our own test room, with all computers and fans turned off, has a room noise level of 36.4dB.
Procedures for measuring cooling system noise are described on page 7 which reports measured noise results comparing the stock Intel cooler and recently tested CPU coolers to the Enzotech Ultra-X.
The standard test bed for cooling tests is the EVGA NVIDIA 680i SLI motherboard. This is primarily based on the consistent test results on this board and the NVIDIA Monitor temperature measurement utility, which is part of the nTune program.
NVIDIA Monitor has a drop-down pane for temperature measurement which reports CPU, System, and GPU measurement. At this point reviews will concentrate on CPU temperature. In addition to the real-time temperature measurement, NVIDIA Monitor also has a logging feature which can record temperature in a file in standard increments (we selected every 4 seconds). This allows recording of temperatures during testing, which can then be reviewed when the stress tests are completed. There is also the handy reference of speeds and voltages in the top pane to confirm setup.
NVIDIA Monitor was compared to test results from the Intel TAT (Thermal Analysis Tool). Intel TAT CPU portions do function properly on the EVGA 680i motherboard, but the chipset-specific features do not operate as they should. Idle temperatures in TAT were in line with measured idle temps with NVIDIA Monitor. The CPU stress testing with TAT pushing both cores showed TAT stress temps at 80% CPU usage roughly corresponded to temps reported in our real-world gaming benchmark.
Other components in the cooling test bed are generally the same as those used in our motherboard and memory test bed:
Cooling Performance Test Configuration | |
Processor | Intel Core 2 Duo X6800 (x2, 2.93GHz, 4MB Unified Cache) |
RAM | 2x1GB Corsair Dominator PC2-8888 (DDR2-1111) |
Hard Drive(s) | Hitachi 250GB SATA2 enabled (16MB Buffer) |
Video Card | 1 x EVGA 7900GTX - All Standard Tests |
Platform Drivers | NVIDIA 9.53 |
NVIDIA nTune | 5.05.22.00 (1/16/2007) |
Video Drivers | NVIDIA 93.71 |
CPU Cooling | Enzotech Ultra-X 3RSystem iCEAGE Thermaltake Big Typhoon VX Thermaltake MaxOrb Scythe Andy Samurai Master Cooler Master Gemini II Noctua NH-U12F ASUS Silent Square Pro Scythe Ninja Plus Rev. B OCZ Vindicator Thermalright Ultra-120 Extreme Thermalright Ultra-120 Scythe Infinity Zalman CNS9700 Zalman CNS9500 Cooler Master Hyper 6+ Vigor Monsoon II Lite Thermalright MST-9775 Scythe Katana Tuniq Tower 120 Intel Stock HSF for X6800 |
Power Supply | OCZ PowerStream 520W |
Motherboards | EVGA nForce 680i SLI (NVIDIA 680i) |
Operating System | Windows XP Professional SP2 |
BIOS | Award P26 (1/12/2007) |
All cooling tests are run with the components mounted in a standard mid-tower case. The idle and stress temperature tests are run with the case closed and standing as it would in most home setups. We do not use auxiliary fans in the test cooling case, except for the Northbridge fan attached to the 680i for overclocking. Room temperature is measured before beginning the cooler tests and is maintained in the 20 to 22C (68 to 72F) range for all testing.
Enzotech provided a small tube of premium Arctic Silver 5 with the cooler accessories, but we tested the Ultra-X with our standard premium silver-colored thermal compound. In our experience the thermal compound used makes little to no difference in cooling test results. This is particularly true now that processors ship with a large manufacturer-installed heatspreader. Our current test procedure uses this standard high-quality silver-colored thermal paste for all cooler reviews.
We test the stock Intel cooler at standard X6800 speed, measuring the CPU temperature at idle and while the CPU is being stressed. The CPU is stressed by running continuous loops of the Far Cry River demo. The same tests are repeated at the highest stable overclock we can achieve with the stock cooler. Stable in this case means the ability to handle our Far Cry looping for at least 30 minutes.
The same benchmarks are then run on the cooler under test at stock, highest stock cooler OC speed (3.73GHz), and the highest OC that can be achieved in the same setup with the cooler being tested. This allows measurement of the cooling efficiency of the test unit compared to stock and the improvement in overclocking capabilities, if any, from using the test cooler.
Noise Levels
In addition to cooling efficiency and overclocking abilities, users shopping for CPU cooling solutions may also be interested in the noise levels of the cooling devices they are considering. Noise levels are measured with the case on its side using a C.E.M. DT-8850 Sound Level meter.
This meter allows accurate sound level measurements from 35bdB to 130dB with a resolution of 0.1dB and an accuracy of 1.5dB. This is sufficient for our needs in these tests, as measurement starts at the level of a relatively quiet room. Our own test room, with all computers and fans turned off, has a room noise level of 36.4dB.
Procedures for measuring cooling system noise are described on page 7 which reports measured noise results comparing the stock Intel cooler and recently tested CPU coolers to the Enzotech Ultra-X.
33 Comments
View All Comments
homonaut - Wednesday, June 27, 2007 - link
I was contemplating getting one of these after stumbling onto this 'review': http://www.coolaler.com/modules/news/article.php?s...">http://www.coolaler.com/modules/news/article.php?s... but now I don't know. How can the results be so different!?SilthDraeth - Wednesday, June 27, 2007 - link
Since I don't speak Chinese or Korean, etc, all I could do was look at the pictures. It is unclear what temps are load or not.Also, they use different processors. Anand uses a 6800 vs a 6600.
They both post a 43 degree celcius temp, on Anand thats a load temp at stock speed, so that might be load on the coolaler site. and the lower temps might be idel temps for the 6600.
idle temp might have been taken at a different time frame for how long the processor was running before the temperature was taken, etc.
The temps do not look to be a huge disparity though imo.
Wesley Fink - Wednesday, June 27, 2007 - link
The Enzotech could boot as high as 3.90 GHz, which is as good as any of the best coolers tested except the Ultra-120 eXtrme which reaches a stable 3.94GHz. All was fine at idle at 3.9GHz, but as soon as we began our stress testing with the game that is about 80% CPU load the system would fail with the Enzothec. This was with the fan on high, near 90 cfm at a pretty loud noise level. We could not even make it through one loop of the game demo, and our stress test procedure runs the game loop for 30 minutes to test load stability.We also tried adding a high output case can as some readers have suggested. This DID lower the CPU temperature, particularly at stock speed strangely enough, however it did not extend overclocking ability at all.